Durite 0-856-10, 12VDC 1000W modified wave voltage inverter.
- Input: 12V to 15V DC.
- Output: 230VAC 50Hz.
- Rated at 1000 Watts, continuous.
- Quiescent (inactive) current less than 0.50A.
- Remote available to purchase separately, part number: 0-856-98
Protection Against
- Overload.
- Over-temperature.
- Low battery.
- High input voltage.
- Short circuit.
Supplied With
- A standard 3-Pin socket outlet.
- On-Off switch.
- LED indicators for voltage and consumption.
Dimensions
- Length: 240mm.
- Width: 363mm.
- Height: 76mm.
Warnings for Translation
- Read all instructions before attempting to install or use the inverter.
- High voltage, 230 Volts AC, is generated by this unit.
- Do not use it with wet hands or near water.
- This unit is only suitable for 12 Volts DC electrical systems with negative earth.
- To supply 230 Volts 50 Hz loads of < 1000 Watts.
- Do not connect to any other AC power source.
Installation Instructions
Disconnect all battery leads, -ve leads first, before installing the inverter.
Locate a suitable position for the inverter and fit it securely. The site chosen should be:
- Well ventilated.
- Not exposed to direct sunlight or heat source.
- Away from water or moisture.
- Out of reach of children.
- Away from any flammable or heat-sensitive substance.
Connect the Black 12 Volts -ve terminal to the negative side of the supply source and the Red 12 Volts +ve terminal to a fused positive supply source. Use a minimum of 16.0mm² cable and keep all cable runs as short as possible.
Connect the inverter case ground terminal to the chassis ground when installing in a vehicle, the vessel’s grounding system in a boat or to earth in a fixed location. The case ground terminal is connected to the ground terminal in the AC outlet socket.
If using an additional remote control (part number to purchase: 0-856-98), fix the remote control in a suitable position and insert the connector into the remote control socket on the inverter control panel.
Operating Instructions
- Ensure that the inverter is supplied by a 12-14 Volts DC negative earth system and that the load requires <1000 Watts at 230 Volts 50Hz AC.
- Plug the appliance into the inverter and then turn on the inverter’s power switch. The LED will illuminate to indicate AC power is present, then switch on the appliance. Always turn on the inverter before turning on loads individually. If using the optional remote control, ensure the control panel power switch is set to ‘Remote’, then use the remote ‘On/Off' switch as the inverter power switch.
- Switch off the inverter when not in use or when heavy current is drawn from the DC supply, e.g. when starting an engine from the same supply source.
- Battery voltage and current bar graphs indicate supply voltage and current. In normal operation, the inverter will operate in the green region. The inverter can operate for short periods in the current yellow zone, and a protective shutdown will occur if used in the red zone.
- If the inverter beeps but is still supplying AC output, this indicates a low supply voltage; switch off the inverter to preserve battery voltage. If left on, the inverter will automatically shut down when the supply voltage falls to approximately 10.0 ± 0.5 Volts.
- The Overtemp indicator illuminates when the inverter has shut down due to overheating. The inverter will restart automatically once it has cooled down.
- The overload indicator illuminates when the inverter has shut down due to output short-circuit or gross overloading. If this occurs, switch the inverter off and correct the cause before switching the inverter on again.
Troubleshooting
If the inverter beeps or does not appear to be functioning properly, check the following:
- Low dc supply voltage, supply voltage <10 .5 ± 0.5 Volts.
- Low dc voltage shutdown, supply voltage <10.0 ± 0.5 Volts.
- Overload shutdown, check load requirement is <1000 Watts.
- Thermal shutdown, switch off, allow the inverter to cool down and reduce load.
- Wiring, terminals and connections.
Remote available to purchase separate part number: 0-856-98.
Specifications
DC Input
12VDC (12V to 15V DC)
Output Waveform
Modified Wave
Continuous Output Power
1000 Watts
Surge Output Power (5 seconds)
2000 Watts
No Load Current
Less than 0.6A
Battery Low Voltage Alarm
10.5 ± 0.5 VDC
Battery Low Voltage Shutdown
10.0 ± 0.5 VDC
Over Temperature Protection
55°C ± 5°C
Outlet
Standard UK 3-Pin 230V socket
Short Circuit Protection
Yes
Dimensions
240mm x 363mm x 76mm